Specifications |
| |
RS-232 to PC |
RJ-11 to DB9 female cable |
| |
RS-485+ |
Connect to GV-IO / PT-811 RS-485+ or Pelco, Ademco, Lilin Dome camera RS-485+ |
| |
RS-485- |
Connect to GV-IO / PT-811 RS-485 - or Pelco, Ademco, Lilin Dome camera RS-485- |
| |
Input |
Input |
4 |
| Input Signal |
5V DC (floating) / TTL |
| High State |
5V |
| Low State |
0V |
| |
Output |
Relay Output |
4 |
| Relay Status |
Normal Open |
| Relay Capacitance |
2A / 30V DC; 0.25A / 125V (250V) AC |
| Relay ON Time |
4ms |
| Relay Off Time |
4ms |
| |
Communication |
RS-485, 1,200~19,200 bps |
| |
RS-485- |
Connect to GV-NET RS-485- |
| |
DC in |
Power adapter DC 5V, 2A inner positive |
| |
Environmental conditions |
Operation temperature |
0~50 Degree C |
| Humidity |
5%~95% (non-condensing) |
| |
Compatible Models |
GV-NET Card: all models |
| |
|
GV-NET/IO Card: GV-600 V3, GV-650 V3, GV-800 V3, GV-900 V1.11, GV-1000 V1.21,
GV-1120, GV-1240, GV-1480 |
| |
Dimension |
88 (W) x 99 (H) mm |
| |
Installation Guide |
Please contact us... |
|